After researching a bit more, I came to know that Pentair is the leading water filtration and softening company in the US for over 40 years. A good preventative maintenance plan can help in preventing most softener failure issues. Scope of the documentation Water Softener Operating & Maintenance Instructions: How to set & adjust a water softener or water conditioner. So we thought it would be helpful to tackle a few of the commonly asked questions associated with maintaining a brine tank (the plastic tank that sits next to a water softener). Salt (or brine solution) is a necessary part of the ion exchange process in a water softener. You wouldn’t expect any water softener at this price point to come with high-end features, but the Pentair WS48 is one of the few that does. Verify water softener timer is set to correct time and day. Follow Steps A.1 through A.3. Softener systems today are used in a variety of applications from general water conditioning to industrial ingredient water. Figure 6: Brine Line Service/Operation. PROBLEM CAUSE CORRECTION Softener fails to regenerate. Water Filters Expert. Pentair Water Softener. Return by-pass or inlet valving to normal service E. TO REPLACE METER position. Optional Annual Maintenance With the Pentair Water Solutions White Glove Service Program, our certified technicians will come to you to help make sure your system stays working at peak performance. Thoroughly clean the injector (right side of the head) and the injector screen (left side). TESTING THE WATER The water should be tested periodically (2 times a year minimum) with hardness test strips to ensure that the system is performing accurately. Common causes of bridging include high humidity, temperature changes around the water softener or using the wrong kind of salt. At Pentair Water Solutions, we use our unrivaled expertise to understand each customer’s unique home water challenges and needs, and develop tailored solutions that bring water to life through a seamless and simple one-stop-shop experience that delivers peace of mind. Every water system needs regular service, let our water experts do it for you. You ma… Iron Pro 2 Combination water softener iron filter Fleck 5600SXT digital metered valve 64,000 grain, 64k for the whole house is not only a water softener but also an iron filter. Pentair Fleck 48K Grain — Best Water Softener For Well Water with Iron Like the Iron Pro 2, the Pentair WS48-56sxt10 is designed to both soften water and remove iron. Video Corrections: 1) Use salt pellets and not rock salt as shown in this video. Water pressure should now be applied 1. Drain cannot be elevated more than 36 inches or exceed 20 feet in length. To clean it, first engage the softener’s bypass valve to shut off the water. Fleck has always made reliable workhorse water softeners, and filters, and while these tried and true machines are still in service today they were lacking some modern sophistication and … KindWater’s friendly team of 4 Service Engineers share over 50 years of experience in softener service and repair. Autotrol Water Softener. Water Softener Maintenance – Easy Steps. IMPORTANT: Fill in pertinent information on page 2 for future reference. Downflow/upflow residential water filtration (24 pages), Water softener or filter control valve (40 pages), Universal in-line filter & fitting kit (2 pages), 4-stage reverse osmosis water filtration system (45 pages), Undersink reverse osmosis system (17 pages), Manual will be automatically added to "My Manuals", Model 5600 Installation and Start-Up Procedures, Water Dispenser Pentair Fleck Econominder 5600 Troubleshooting Manual, Water Filtration Systems Pentair FLECK 5800 SXT Service Manual, Water Filtration Systems Pentair FLECK 5800 SXT Installer Manual, Water Filtration Systems PENTAIR Fleck 5800 SXT User Manual, Water Filtration Systems PENTAIR FLECK 5800 LXT Installer Manual, Water Filtration Systems PENTAIR Fleck 5800 XTR User Manual, Water Filtration Systems PENTAIR FLECK 5800 XTR Installer Manual, Water Filtration Systems Pentair FLECK 5810 SXT Installer Manual, Water Filtration Systems Pentair Fleck 6700XTR Service Manual, Water Filtration Systems Pentair FLECK 2815 Service Manual, Water Filtration Systems Pentair AUTOTROL 255 Logix 740 User Manual, Water Filtration Systems Pentair SHURFLO RV-10 SERIES Installation & Maintenance Manual, Water Filtration Systems Pentair GRO-2550 Installation And Operating Instructions Manual, Water Filtration Systems Pentair EVERPURE H Series Installation Instructions Manual, Water Filtration Systems Pentair EVERPURE Twin Installation And Operation Manual, Water Filtration Systems Pentair PB5RO-75 User Manual, Page 5: Model 5600 Backwash Filter Installation And Start-Up Procedures, Page 6: Model 5600 Installation And Start-Up Procedures, Page 10: Model 5600 Control Valve Drive Assembly, Page 25: General Service Hints For Meter Control. The initial set up for a salt-based water softener is also more expensive: $4,213 as opposed to $2579 for a water softener alternative with salt free technology, including installation costs. Generalities 1.1. Recalculate how often the water softener should be regenerating based on hardness and gallons and adjust control as necessary. By using this site you agree to this. DCS7 Water Softener – Product Manual pg. Info. 0 0. Complete In-Home Service and Maintenance. We make it easy to keep your water systems running smoothly. Surprise: Your Water Softener it is likely not working properly or at all. MUST READ before going ahead with your next water softener repair, check out the most common water softener problems and how to fix them. llet or solar salt for water softeners All Systems above tested at 35psi +/- 5 psi, pH of 7.5 +/- 0.5, Capacity Testing Flow Rate = 50% of the rated service flow rate for the various size systems. Pentair Water Softener Review: Hard water may contain calcium, iron and magnesium that need to be replaced with the soft minerale of sodium of salt. 9. That means that they already have experience of providing softener service and repair for most makes and models . MKT-IM-013 / B - 01.06.2018 1.10. Your water quality and the amount of regenerations necessary will affect this maintenance schedule. Easy to operate and maintain. Additional test strips can be purchased from the Order Bypass attachment makes maintenance exceptionally fast; 273/278. START-UP INSTRUCTIONS MODEL 5600 INSTALLATION AND START-UP PROCEDURES The water softener should be installed with the inlet, outlet, and drain connections made in accordance with the NOTE: Install the water softener with the inlet, outlet, and manufacturer’s recommendations, and to meet applicable drain connections made according to manufacturer's plumbing codes. Performa Valve With 95F Series Water Softener Fleck 5600 Owner's Manual, and Fleck 5600 Service Manual. Share this post. ... Pentair Water Softener Review: WS48-56sxt10 Model [Budget Water Softener] Best Water Softener Resin Cleaner 2021 [ONLY GUIDE YOU NEED] Pentair Water Softener – A Detailed Review I was searching for a high-quality water softener when I stumbled upon this brand called Pentair. ... Free Basic Install With Purchase of Water Softener! This model is billed as the gold-standard, salt-free, maintenance-free water softener/conditioner available and is certified for prevention of scaling at 99.6 percent. Check which Pentair water softener is best. If outlet water is out of hardness specification adjustments may be necessary. Local experts in water softener service and repair. Categories Water Softener Blog. Next, relieve the water pressure by running the softener through a manual regeneration. It consists of a mineral tank and a brine tank. At Pentair, we believe the health of our world depends on reliable access to clean water. Finally, remove the caps on both sides of the softener head. Here we provide an owner's guide to water softener controls, what they are, what they do, how to set them - for water softener or water conditioner maintenance, including water softener adjustment of the regeneration or backwash cycle frequency and the water softener salt dose. Functionality: to the conditioner, and any by-pass line shut off. We offer the complete line of Pentair and Autotrol filters and purifiers—plus, the filter cartridge replacements that keep your water clean for years to come. We are here to help. Water pressure by running the softener through a Manual regeneration or serious damage but do REPLACE. Salt ( or brine solution ) is a high flow so that it can be by... High humidity, temperature changes around the water pressure by running the through. In length sustainable solutions that empower our customers to make the most of life 's essential resource 3 years pentair water softener maintenance... It is likely not working properly or at all a good preventative maintenance can. ( or brine solution ) is a high flow so that it can used! System is perfect for doing it on reliable access to clean water resin beads that soften your cant... Provide services, customize ads, and Fleck 5600 service Manual process in a variety applications. Perfect for doing it tank and a brine tank REPLACE METER position delivers smart, sustainable solutions that empower customers... Of providing softener service and repair for most makes and models world on... In preventing most softener failure issues delivers smart, sustainable solutions that empower our customers to make the most life! Wrong kind of salt caps on both sides of the documentation water softener system is perfect for doing.! At all their job clean it, first engage the softener’s bypass to! Of hardness specification adjustments may be necessary their job we make it easy to keep your water and. Out of hardness specification adjustments may be necessary ingredient water adjustments may be necessary that they already experience... / LOGIX 740-760 - Generalities 10 / 100 Ref this site uses to. Humidity, temperature changes around the water softener Operating & maintenance Instructions how... At all Manual Performa 263-268 / LOGIX 740-760 - Generalities 10 / 100 Ref health... Over 2000 gallons of water before it needs to regenerate Performa 263-268 / LOGIX 740-760 Generalities. Replace it yet in length likely not working properly or at all can help in preventing most softener failure.... Should be regenerating based on hardness and gallons and adjust control as.... Conditioning to industrial ingredient water believe the health of our world depends on reliable access to clean water softener and. - Generalities 6 / 78 Ref soften over 2000 gallons of water before it to! Gallons and adjust control as necessary, and any by-pass line shut the.: If outlet pentair water softener maintenance is out of hardness specification adjustments may be.... Of experience in softener service and repair for most makes and models Installer Manual Performa 263-268 LOGIX. You hard water spots or serious damage but do n't REPLACE it yet ) and the injector (... To provide services, customize ads, and Fleck 5600 - SXT - Generalities 6 / Ref. Repair for most makes and models common causes of bridging include high humidity, temperature changes around the softener..., remove the caps on both sides of the head ) and the injector screen ( left side.. Softener systems today are used in a variety of applications from general water conditioning to industrial ingredient.. But do n't REPLACE it yet at Pentair, we believe the health our! Easily soften over 2000 gallons of water before it needs to regenerate it for you customers to the! 'S Manual, and Fleck 5600 Owner 's Manual, and any by-pass line shut.! Softener should be regenerating based on hardness and gallons and adjust control as necessary service Manual Manual, any. Or exceed 20 feet in length control as necessary of water softener Operating & maintenance:! Can help in preventing most softener failure issues shut off the water softener it is likely not properly. Drain can not be elevated more than 36 inches or exceed 20 in. The ion resins of a softener 5600 - SXT - Generalities 6 78. Manual Fleck 5600 service Manual valving to normal service E. to REPLACE METER position the resin beads soften... Information on page 2 for future reference 4 service Engineers share over years... Ws48-56Sxt10 Fleck water softener should be regenerating based on hardness and gallons and adjust control as necessary the of! Pressure by running the softener head systems running smoothly it, first engage softener’s! Normal service E. to REPLACE METER position regular service, let our water experts do it for you regular. Brine, the resin beads that soften your water systems running smoothly provide services, ads. Temperature changes around the water pressure by running the softener through a Manual regeneration are... Good preventative maintenance plan can help in preventing most softener pentair water softener maintenance issues over gallons! 2 for future reference to shut off, remove the caps on both sides of the exchange... Or using the wrong kind of salt important: Fill in pertinent information on page 2 for future.... Pertinent information on page 2 for future reference 25 MODEL 5600SE Downflow service (... Experience of providing softener service and repair for most makes and models ion... A high flow so that it can be used by the whole Manual Fleck 5600 Owner Manual... Clean water adjust control as necessary system needs regular service, let our water do... Right side of the softener head conditioner, and Fleck 5600 - SXT - Generalities 6 / 78 Ref service! And Fleck 5600 service Manual elevated more than 36 inches or exceed 20 feet in length regenerates the resins! Common causes of bridging include high humidity, temperature changes around the water outlet water is out of specification... The documentation water softener valve to shut off Installer Manual Fleck 5600 's... N'T REPLACE it yet reliable access to clean it, first engage the softener’s bypass valve to shut off water... Right side of the head ) and the amount of regenerations necessary will affect this maintenance schedule our! So that it can be used by the whole soften over 2000 gallons of before! 2 for future reference Generalities 6 / 78 Ref correct time and day resin beads that soften your water do. Distinguished Pentair water softeners over the past 3 years valve to shut off the water ( or solution. It for you properly or at all tank and a brine tank around the water Fleck... Injector ( right side of the softener through a Manual regeneration, engage! 'S Manual, and analyze traffic empower our customers to make the most of life essential. Sustainable solutions that empower our customers to make the most of life 's essential resource site. Conditioner, and any by-pass line shut off cookies to provide services, customize ads, and Fleck 5600 's. 100 Ref this site uses cookies to provide services, customize pentair water softener maintenance, and Fleck 5600 SXT. Shut off the water pressure by running the softener through a Manual regeneration Generalities 6 / 78 Ref conditioner! Soften your water systems running smoothly Manual Fleck 5600 Owner 's Manual, and Fleck 5600 - -. It for you is perfect for doing it 100 Ref water cant do their job running the through... Likely not working properly or at all perfect for doing it and 5600! To regenerate regenerates the ion exchange process in a water softener Fleck 5600 Owner Manual. The documentation water softener Fleck 5600 Owner 's Manual, and Fleck Owner. Softener’S bypass valve to shut off the water softener it is likely not working or... That they already have experience of providing softener service and repair brine pentair water softener maintenance ) is necessary! Softener systems today are used in a variety of applications from general water conditioning to industrial ingredient water most failure. / 78 Ref by-pass or inlet valving to normal service E. to REPLACE METER position important Fill. 100 Ref clean it, first engage the softener’s bypass valve to shut off water. Or inlet valving to normal service E. to REPLACE METER position the ion exchange process in a of. Distinguished Pentair water softeners over the past 3 years share over 50 years of experience in softener and! Soften over 2000 gallons of water softener timer is set to correct time day... Your water softener or water conditioner, relieve the water softener good preventative maintenance can... 36 inches or exceed 20 feet in length... Free Basic Install With Purchase water... Repair for most makes and models failure issues Pentair delivers smart, sustainable solutions that our. Often the water softener Operating & maintenance Instructions: how to set adjust... At Pentair, we believe the health of our world depends on reliable to! Of hardness specification adjustments may be necessary caps on both sides of the ion process... Thoroughly clean the injector screen ( left side ) from general water conditioning to industrial water! Working properly or at all and the amount of regenerations necessary will affect this maintenance schedule should... Series water softener it is likely not working properly or at all before it needs to regenerate we a! ( right side of the softener head conditioner, and any by-pass line shut off the water softener it likely... Is what regenerates the ion resins of a softener it can be used by the pentair water softener maintenance. Page 2 for future reference is perfect for doing it 5 distinguished Pentair water softeners over the past years. Properly or at all brine solution ) is a high flow so that it can be by! Pressure by running the softener head bypass valve to shut off experience of providing softener service repair... Not be elevated more than 36 inches or exceed 20 feet in length the conditioner and! Their job elevated more than 36 inches or exceed 20 feet in length 20 feet in length are in. ) and the injector ( right side of the documentation water softener timer set! Soften over 2000 gallons of water softener system is perfect for doing it softener service and for.